Security advisories

As of 19 November 2026

This page describes vulnerabilities fixed in OmniMES: which versions they affect, which version fixes them, how we rate their severity and what you should do. The descriptions leave out details that would make the vulnerabilities easier to exploit.

We rate severity on the CVSS 3.1 scale. We give a numeric score with its vector when it can be determined reliably. Otherwise we give the severity level only.

General recommendation: use the latest OmniMES version. Instances on the OmniPlatform cloud are updated by the manufacturer. We also inform affected customers directly.

OMNI-SA-2026-001

Server command execution when generating a report from a template

Published
2026-11-19
Affects
OmniMES versions earlier than 4.8.0.
Fixed in
4.8.0 (2026-11-14).
Severity
high — CVSS 3.1: 8.8
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Description
A logged-in user, regardless of the permissions assigned, could cause arbitrary commands to run on the application server while generating a report from a template. Since version 4.8.0, report formulas accept only numbers, arithmetic operators and parentheses.
What to do
Update OmniMES to version 4.8.0 or later. Until you update, limit access to the system to trusted users and a trusted network.

OMNI-SA-2026-002

Role permissions not checked by the server (API)

Published
2026-11-19
Affects
OmniMES versions earlier than 4.8.0, and installations upgraded to 4.8.0 or later where permission enforcement has not been enabled.
Fixed in
4.8.0 (2026-11-14). New installations have enforcement enabled from the start; in upgraded installations the administrator enables it.
Severity
high (no numeric score — the impact depends on the roles and data in a given installation)
Description
Group permissions from the Access screen only limited what users saw in the browser. A logged-in user could use the API, bypassing the interface, to read and change data outside their assigned screens, including passwords and keys stored in General configuration and other users' accounts. Since version 4.8.0 the server checks permissions on read and write, and administrative and service accounts can be changed only by the main administrator, regardless of the mode.
What to do
Update to version 4.8.0 or later. In an installation upgraded from an earlier version, enable permission enforcement (OMNIMES_RBAC_MODE=enforce) after reviewing the denial report — see the Installation chapter, section “System update”. If users outside the administration team had access to the system, also change the passwords and keys stored in General configuration (e.g. the mail password, AI service keys).

OMNI-SA-2026-003

Other users' login credentials readable

Published
2026-11-19
Affects
OmniMES versions earlier than 4.8.0.
Fixed in
4.8.0 (2026-11-14).
Severity
high (no numeric score — the impact depends on whose credentials were read)
Description
A logged-in user could read another person's password, including an administrator's, and — through the backup module — API access tokens of other accounts. Since version 4.8.0 passwords are not available to other accounts, backups do not contain tokens, and only the main administrator can import a backup containing user accounts.
What to do
Update to version 4.8.0 or later, then change the passwords of administrative accounts. If you suspect the vulnerability may have been exploited, contact us — we will help you revoke access tokens.

OMNI-SA-2026-004

BI data available without authentication

Published
2026-11-19
Affects
OmniMES versions earlier than 4.7.0, and installations from 4.7.0 on where BI data access runs in the “otwarty” (open) or “loguj” (log, default) mode.
Fixed in
4.7.0 (2026-11-13). The administrator enables the “wymagaj” (require) mode.
Severity
medium (no numeric score — it depends on who has network access to the OmniMES API)
Description
The interface from which Redash dashboards fetch production data answered requests without authentication. Anyone with network access to the OmniMES API could read that data. Since version 4.7.0 Redash fetches the data with the token of a service account that can only read it, and the “wymagaj” mode rejects requests without a token.
What to do
Update to version 4.7.0 or later. Use the report described in BEZPIECZENSTWO_API.md (in the installation package) to check that there were no requests without a token over the last 7 days, then set OMNIMES_DATABI_AUTH=wymagaj.

Changes that strengthen security without fixing a specific vulnerability are listed in the Security section of the changelog. Changelog

Questions about these advisories: support@omnimes.com.

How to report a vulnerability